Tektronix IsoVu Isolated Current Probes
TICP Series IsoVuTM Isolated Current Probes make accurate, low-noise, dynamic current measurements using shunt and current viewing resistors, even in the presence of fast-changing common mode voltages that occur on floating devices in power circuits.
- Bandwidth: Up to 1GHz
- Common Mode Voltage: 1.8kV max
- Noise Contribution: 150µVRMS@ 1GHz
- Common Mode Rejection: Up to 140dB
A Breakthrough in Oscilloscope Current Measurements
TICP current probes enable measurements from DC to hundreds of MHz when paired with high-performance shunts or CVRs. Choose from three models to fit your application and budget.
Complete RF isolation between the probe tip and the scope eliminates ground loops and dramatically reduces common mode noise.
Low attenuation, 50 Ω input impedance, and shielded tips ensure a low noise contribution.
- Three bandwidths: 250 MHz, 500 MHz, 1 GHz
- Up to 90 dB CMRR @ 1 MHz
- Noise contribution < 4.7 nV/√Hz (<150 µV at 1 GHz)
Gain New Insights into SiC and GaN Power Converters
For measuring fast-changing currents in wide bandgap switching devices, shunt probes can deliver more bandwidth than clamp-on probes. IsoVu isolation eliminates ground loops, enables measurements on high-voltage circuits, and provides extremely high CMRR. This makes TICP probes ideal for current measurements on shunts and CVRs on high-side SiC and GaN switching FETs.
- 250 MHz, 500 MHz, or 1 GHz bandwidth
- 1800 VRMS Common mode voltage
- Up to 90 dB CMRR @ 1 MHz
- 1000 V CAT II Safety rating
Combine with IsoVu Voltage Probes for a low-noise picture of switching performance.
Measure Current Draw in Nanoseconds and Microamps in Low Power Designs
Accurately measuring low-level, dynamic currents can be critical for optimizing power management in IoT and mobile devices. With TICP probes and shunts, along with your oscilloscope, you’ll be able to see current consumption during specific system activities and transitions from sleep to active states, correlated with memory accesses and I/O.
- Bandwidth up to 1 GHz
- Noise contribution < 4.7 nV/√Hz (<150 µV at 1 GHz)
- Easily measure 12, 24 or 48 V rails, or higher
Combine with Power Rail Probes for multi-rail analysis of power distribution networks.
Minimize Connection Hassles
TICP probes and tips are designed to minimize connection hassles while limiting noise. Tips are designed to bend easily to reduce strain on connections and promote easy reliable connections to your DUT.
- Tips terminate in shielded, high-bandwidth MMCX connectors
- Use with off-the-shelf adapters for SMA or BNC connectors
- Adapt to 25 mil square pins for connection to on-board shunts and test points
- Included bipod and tripod adapters for stability
Seamless Integration with 4, 5 and 6 Series MSO Oscilloscopes
4, 5 and 6 Series MSO oscilloscopes are known for their advanced power analysis capabilities. IsoVu current probes are designed to work seamlessly with these instruments. The TekVPITM probe interface powers the probe, and automatically detects the probe and tip, allowing you to adjust probe parameters from the scope user interface. This also enables test automation using the oscilloscopes’ programming commands.
Model | Description |
---|---|
TICP025 | Tektronix Isolated Current Probe 250MHz |
TICP050 | Tektronix Isolated Current Probe 500MHz |
TICP100 | Tektronix Isolated Current Probe 1GHz |
Probe Tips | SMA Input | 1X MMCX Tip | 10X MMCX Tip | 100X MMCX Tip |
---|---|---|---|---|
Dynamic range and maximum voltage | ±0.5 V | ±5 V | ±50 V | |
Input resistance | 50 Ω | 500 Ω | 5000 Ω | |
Capacitance | - | < 3 pF |
Model | Description |
---|---|
Standard Accessories |
|
TICPMM1 | 1X sensor tip cable with MMCX connector |
TICPMM10 | 10X sensor tip cable with MMCX connector |
TICPSMA | SMA tip adapter |
131-9717-00 | Square-pin to MMCX adapter |
276-0905-00 | Clamp-On Ferrite Common Mode Choke |
103-0508-xx | Tripod adapter for ¼”-20 UNC Thead accessories |
352-1179-xx | Probe bipod stand |
- | Soft carrying case with custom foam insert |
Warranty | 1-year standard |
Optional Accessories |
|
TICPMM100 | 100X sensor tip cable with MMCX connector |
Supported oscilloscopes
- 4 Series MSO, 4 Series B MSO
- 5 Series MSO, 5 Series B MSO, 5 Series MSO LP
- 6 Series MSO, 6 Series B MSO
Add extended service and calibration
Optimize the lifetime value of your purchase and lower your total cost of ownership with a calibration and extended warranty plan for your instrument.
Plans range from standard warranty extensions covering parts, labor, and 2-day shipping to Total Product Protection with repair or replacement coverage from wear and tear, accidental damage, ESD or EOS. See the table below for specific service options available.
Service Option | Description | |
---|---|---|
Warranty Extension | ||
R3 | Standard warranty extended to 3 years. Covers parts, labor and 2-day shipping within country. Guarantees faster repair time than without coverage. All repairs include calibration and updates. Hassle free - a single call starts the process. | Contact Testforce Sales Office. |
R5 | Standard warranty extended to 5 years. Covers parts, labor and 2-day shipping within country. Guarantees faster repair time than without coverage. All repairs include calibration and updates. Hassle free - a single call starts the process. | |
Calibration Coverage | ||
C3 | Option C3: Calibration service 3 years.Includes traceable calibration or functional verification where applicable, for recommended calibrations. Coverage includes the initial calibration plus 2 years calibration coverage. | Contact Testforce Sales Office. |
C5 | Option C5: Calibration service 5 years.Includes traceable calibration or functional verification where applicable, for recommended calibrations. Coverage includes the initial calibration plus 4 years calibration coverage. | |
Data Reports | ||
D1 | Calibration Data Report | Contact Testforce Sales Office. |
D3 | Calibration Data Report 3 Years (with Option C3) | |
D5 | Calibration Data Report 5 Years (with Option C5) |
Contact Us for details