The DPO7OE series optical probes with a DPO70000 real-time scope deliver the performance and advanced debug capabilities designers need to fully troubleshoot 400G PAM4 signals, up to 56 GBaud, and reduce time to market.
These probes can also be used as a conventional O/E with flat response filter for general laser signal acquisition up to their respective bandwidth of 33 GHz or 59 GHz.
The DPO7OE Series Optical probes can be used as Optical Reference Receivers (ORR) for high speed serial data signals (using selectable Bessel-Thomson ORR filters), or can be used as a conventional O/E converter for general wide-bandwidth optical signal acquisition. The DPO7OE Series is compatible with DPO/MSO70000 C/DX/SX models. Connect to TekConnect channels for up to 33 GHz electrical bandwidth. Connected to ATI channels, the DPO7OE1 provides up to 42 GHz electrical response; the DPO7OE2 provides up to 59 GHz electrical bandwidth response.
Features and benefits
- Accurate Optical Reference Receiver (ORR) filters for 25 GBd, 26 GBd, 28 GBd, and 53 GBd optical networking standards ensure highest measurement accuracy and correlation
- Versatile design delivers Bessel-Thompson ORR specified bandwidths or unfiltered response up to 59 GHz on multiple channels
- Broad wavelength with FC/PC or FC/APC connector options
- High sensitivity and low noise provide best SNR for high-speed signal analysis
- Enables deep analysis of PAM4 and PAM2 (NRZ) signaling, equalization and error detection/isolation
- Compatible with ATI and TekConnect® channels for maximum performance or channel density
Applications
- Datacenter networking equipment design validation
- Research - Characterization of laser-based velocity measurement system (e.g. PDV, BLR) and other optical phenomena
- System debug of optical interfaces using a real time oscilloscope's unique debug features
Model | Description |
---|---|
DPO7OE1 | 33GHz, single/multi-mode optical probe for MSO/DPO70000 Real Time Oscilloscopes. Wavelength range: 750nm - 1650nm |
DPO7OE2 | 59GHz, single mode optical probe for MSO/DPO70000 Real Time Oscilloscopes. Wavelength range: 1200nm - 1650nm |
Model | Description |
---|---|
- | Hard case |
- | Instruction manual |
- | Certificate of Traceable Calibration |
- | Optical fiber cleaning tool |
- | ATI input support accessory |
Warranty | One year warranty |
Supported oscilloscopes
The DPO7OE Series is compatible with DPO/MSO70000 C/DX/SX models.
Add extended service and calibration
Optimize the lifetime value of your purchase and lower your total cost of ownership with a calibration and extended warranty plan for your instrument.
Plans range from standard warranty extensions covering parts, labor, and 2-day shipping to Total Product Protection with repair or replacement coverage from wear and tear, accidental damage, ESD or EOS. See the table below for specific service options available.
Extended service and calibration options
Service Option | Description | |
---|---|---|
Warranty Extension | ||
R3 | Standard warranty extended to 3 years. Covers parts, labor and 2-day shipping within country. Guarantees faster repair time than without coverage. All repairs include calibration and updates. Hassle free - a single call starts the process. | Contact Testforce Sales Office. |
R5 | Standard warranty extended to 5 years. Covers parts, labor and 2-day shipping within country. Guarantees faster repair time than without coverage. All repairs include calibration andupdates. Hassle free - a single call starts the process. | |
Gold Care Plans | ||
G3 | Three Year Gold Care Plan. Includes expedited repair of all product failures including ESD and EOS, access to a loaner product during repair or advanced exchange to reduce downtime, priority access to Customer Support among others | Contact Testforce Sales Office. |
G5 | Five Year Gold Care Plan. Includes expedited repair of all product failures including ESD and EOS, access to a loaner product during repair or advanced exchange to reduce downtime, priority access to Customer Support among others | |
Calibration Coverage | ||
C3 | Option C3: Calibration service 3 years.Includes traceable calibration or functional verification where applicable, for recommended calibrations. Coverage includes the initial calibration plus 2 years calibration coverage. | Contact Testforce Sales Office. |
C5 | Option C5: Calibration service 5 years.Includes traceable calibration or functional verification where applicable, for recommended calibrations. Coverage includes the initial calibration plus 4 years calibration coverage. | |
Data Reports | ||
D1 | Calibration Data Report | Contact Testforce Sales Office. |
D3 | Calibration Data Report 3 Years (with Option C3) | |
D5 | Calibration Data Report 5 Years (with Option C5) |