We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
R&S®MXO 4 Oscilloscope
Next generation oscilloscope for accelerated insight
Key facts
- Bandwidth: 200 MHz - 1.5 GHz
- World’s first oscilloscope with an update rate > 4.5 million waveforms per second and industry leading spectrum acquisition rate of 45,000 FFT/s, with up to 4 spectra
- Industry-leading system architecture: 18-bit vertical resolution/12-bit ADC, 10-bit ENOB
- Zone trigger on analog, spectrum and math
- Deepest in class standard memory: 400 Mpoints
NEXT GENERATION TECHNOLOGY
The R&S®MXO 4 series is the first of a new generation of oscilloscopes that excels in both performance and value. The instruments deliver a once-in-a-decade engineering breakthrough for accelerated insight.
They have the world’s fastest real-time update rate of 4.5 million waveforms/s, meaning engineers can see more infrequent events than with any other instrument. The 12-bit ADC in the R&S®MXO 4 series has 16 times the resolution of traditional 8-bit oscilloscopes at all sample rates for more precise measurements without any compromises. A standard 400 Mpoint acquisition memory on all four channels and an optional 800 Mpoint interleaved memory provide the instrument with up to 100 times the standard memory of comparable instruments.
A class above similar oscilloscopes, R&S®MXO 4 series oscilloscopes sport an impressive 13.3" Full HD capacitive touchscreen and an intuitive user interface with a learning curve of less than 15 minutes.
Find signal anomalies quickly
... with unparalleled update rate
- > 4.5 million waveforms/s.
- Up to 90 % real-time signal capture
- Fast performance with active automatic measurements, FFT or cursor measurements
- Quickly and reliably detect sporadic signal faults
See your signals accurately
… with lowest measurement noise and highest vertical resolution
- 12 bit ADC vertical resolution at all sample rates without compromise
- 18 bit architecture with HD mode
- Vertical scaling down to 500 μV/div at full bandwidth
- Industry’s highest available counteract range of ±5 V at 500 μV/div
Capture more time
… with the deepest standard memory
- Industry’s deepest memory of 400 Mpoints per channel
- Standard segmented memory with 10,000 segments
- Standard history mode with 10,000 acquisitions
Isolate events
… with high-precision digital trigger
- Industry's most sensitive trigger: 1/10,000 vertical division
- Best in class trigger jitter of just 1 ps
- World’s fastest trigger rearm time of < 21 ns
- Adjustable digital trigger filters and hysteresis
- Zone trigger capability on analog, spectrum and math waveforms
Superior user experience
… with advanced usability designed for touch
- Quick access to important tools
- R&S®SmartGrid for individual waveform layouts with drag and drop
- Enhanced touch sensitivity when changing important parameter values
- Find features and functions faster with the new search menu
- Remote control access wherever and whenever you need it
Powerful spectrum analysis
... with dedicated RF controls
- Obtain RF insights into your measurements with up to 45,000 FFT/s
- Pristine RF characteristics for great spectrum performance
- Analysis made easy with dedicated Radio Frequency controls
- Spectrum and time domain views, all time-correlated with independent controls
- Automatic measurements such as peak lists, max./min. hold
Model | Description |
---|---|
R&S®MXO44-242 | R&S® MXO 4 series: 4 channel oscilloscope, 200 MHz bandwidth, upgradable to 350MHz, 500MHz, 1GHz on 4ch and 1.5GHz on 2ch - 12-bit ADC & 18-bit in HD mode - 4.5Mwfms/s acquisition rate - 400Mpts acquisition memory - 5 Gsample/s sample rate - 4 passive 700MHz probes |
R&S®MXO44-243 | Package MXO 4 series 4 channel oscilloscope, 350 MHz Contains serialized product+options: R&S®MXO 4 series oscilloscope 4 channels 1335.5050K04 consisting of: - R&S®MXO 4 series oscilloscope 4 channel - R&S®MXO4-B243 350 MHz bandwidth upgrade |
R&S®MXO44-245 | Package MXO 4 series 4 channel oscilloscope, 500 MHz Contains serialized product+options: R&S®MXO 4 series oscilloscope 4 channels 1335.5050K04 consisting of: - R&S®MXO 4 series oscilloscope 4 channel - R&S®MXO4-B245 500 MHz bandwidth upgrade |
R&S®MXO44-2410 | Package MXO 4 series 4 channel oscilloscope, 1 GHz Contains serialized product+options: R&S®MXO 4 series oscilloscope 4 channels 1335.5050K04 consisting of: - R&S®MXO 4 series oscilloscope - R&S®MXO4-B2410 1 GHz bandwidth upgrade |
R&S®MXO44-2415 | Package MXO 4 series 4 channel oscilloscope, 1.5 GHz Contains serialized product+options: R&S®MXO 4 series oscilloscope 4 channels 1335.5050K04 consisting of: - R&S®MXO 4 series oscilloscope 4 channel - R&S®MXO4-B2415 1.5 GHz bandwidth upgrade |
Bundles |
|
R&S®MXO4-BNDL | Package MXO 4 series digital oscilloscope 4 channels, Contains serialized product + options: R&S®MXO44 digital oscilloscope 1335.5050K04 consisting of: - R&S®MXO44 digital oscilloscope, 4 channel, 200MHz - R&S®MXO4-B2415 1.5GHz Bandwidth upgrade - R&S®MXO4-PK1 Application bundle -Arbitrary Waveform Generator MXO4-B6 - Power Analysis MXO4-K31 -Frequency&Impedance analysis MXO4-K36 Triggering and decoding for (I2C,SPI,UART/RS-232/-422/-48)MXO4-K510 (CAN,CAN-FD,CAN-XL,LIN) MXO4-K520 |
R&S® Extended Warranty
To make sure you get the full benefit from the functionality and precision of your instruments for the longest possible time, we offer a range of services that are tailored to your specific needs. Choose extended warranty (WE1 to WE4) for complete protection in case of repair, or the attractive extended warranty with calibration coverage package with R&S®Manufacturer-Calibration (CW1 to CW4) or with R&S®Accredited-Calibration (AW1 to AW4) for additional regular calibration of your instrument. The three options are available with terms of one to four years depending on the duration of the standard warranty.
Compare Rohde & Schwarz Extended Warranty Services
Description | Extended Warranty (WE1-4) |
Extended Warranty with Calibration Coverage (CW1-4) |
Extended Warranty with Accredited Calibration Coverage (AW1-4) |
---|---|---|---|
Repair in case of malfunction All repairs during the warranty periodare free of charge. |
|
|
|
Calibration if necessary as part of repair All necessary calibrations will be made during the repair. |
R&S® Manufacturer- Calibration |
R&S® Manufacturer- Calibration |
R&S®Accredited- Calibration |
Planned calibrations in line with Rohde & Schwarz guidelines and ISO/IEC 17025 With our precision test and diagnostics systems we analyze your equipment in detail, to detect and correct irregularities before they impact your measurments. Your instruments stay in top working condition. |
R&S® Manufacturer- Calibration |
R&S®Accredited- Calibration |
|
Calibration as needed as part of hardware upgrades We take care that your Rohde & Schwarz product is regularly calibrated and maintained at the recommended intervals during the warranty period, including also calibrations as part of hardware upgrades to the latest technologies. |
R&S® Manufacturer- Calibration |
R&S®Accredited- Calibration |
|
Firmware updates As part of regular checks, we will update your instrument’s firmware to improve product characteristics, enhance system performance and bring all functions up to date. |
|
|
|
Preventive maintenance and reliability modifications To improve the performance and reliability of your instrument, we maintain it with the greatest care and precision. This naturally includes hardware updates, a service that only the manufacturer can offer. |
|
|
|
Contact us to add any of this services to your R&S products. Click here to read R&S extended warranty brochure. |
R&S® Service Contracts
To make sure you get the full benefit from the functionality and precision of your instruments for the longest possible time, we offer a range of services that are tailored to your specific needs. Choose one of the following packages. All are available with terms of one to five years.
Compare Rohde & Schwarz Services Contracts
Coverage | Repairs | Calibration (R&S® recommended intervals) |
Calibration (R&S® recommended intervals) and repairs |
||
---|---|---|---|---|---|
Product | R1-R5 | C1-C5 | A1-A5 | RC1-RC5 | AR1-AR5 |
Includes | Repair Coverage |
R&S® Manufacturer Calibration | R&S® Accredited Calibration | R&S® Manufacturer Calibration and Repair Coverage | R&S® Accredited Calibration and Repair Coverage |
Repairs |
|
|
|
||
Calibration needed during repair |
|
|
|
|
|
Scheduled calibration in line with Rohde & Schwarz guidelines and ISO/IEC 17025 |
|
|
|
|
|
Calibration as required due to technical upgrade |
|
|
|
|
|
Calibration adjustments for optimimum, reliable performance |
|
|
|
|
|
Firmware updates |
|
|
|
|
|
Preventative maintenance and service modifications |
|
|
|
|
|
If you would prefer to have different contract durations or calibration intervals, or to add any of this services to your R&S products, please Contact us. Click here to read R&S service contracts brochure. |
Service that adds value
- Local and personalized
- Customized and flexible
- Uncompromising quality
- Long-term dependability
Adding services to your order? Contact us for more details.