We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Anritsu MA24108A
Microwave USB Power Sensor
True-RMS USB Power Sensor; 10 MHz - 8 GHz (Includes 2000-1605-R and 2000-1606-R Cables)
The MA24108A power sensor is designed to provide accurate average power measurements from 10 MHz to 8 GHz over 60 dB of dynamic range. The sensor employs a "dual path" architecture that provides (similar to thermal sensor) True-RMS measurements over the entire frequency and dynamic range, enabling users to make highly accurate average power measurements for CW, multi-tone, and digitally modulated signal up to 8 GHz. The sensors have internal and external triggering capability that facilitates individual slot power measurements of TDMA waveforms as well as burst power measurements of periodic and non-periodic waveforms.
The sensor can be controlled with a PC and via PowerXpert™, a free of charge software application. These sensors are also compatible with Anritsu Spectrum Master™, BTS Master™, VNA Master™, and MS271xB Economy Spectrum Analyzers. The sensor easily connects to the instrument via a USB A/micro-B cable. The High Accuracy Power Meter (Option 19) is a software option that enables the desired instrument to interface with the power sensor.
The sensors have internal and external triggering capability that facilitates individual slot power measurements of TDMA waveforms as well as burst power measurements of periodic and non-periodic waveforms.
<4%
Available Accessories
Model | Description |
---|---|
Calibration Torque Wrenches |
|
01-200 | Calibrated torque wrench; GPC-7 and type N |
01-204 | Calibrated torque wrench for K and V connectors |
Power Attenuators |
|
3-1010-123 | Attenuator; 30 dB; 50 Watt; DC-8.5 GHz; N(m)-N(f) |
3-1010-124 | Attenuator; 40 dB; 100 watt; DC-8.5 GHz; N(f) input - N(m) output; Uni-directional |
3-1010-122 | Attenuator; 20 dB; 5 Watt; DC - 12.4 GHz; N(m)-N(f) |
42N50-20 | Attenuator; 20 dB; 5 Watt; DC to 18 GHz; N(m) - N(f) |
42N50A-30 | Attenuator; 30 dB; 50 Watt; DC to 18 GHz; N(m) - N(f) |
41KB-3 | Precision Fixed Attenuator; 3 dB; DC to 26.5 GHz; K(m) - K(f); 50 Ohm |
41KB-6 | Precision Fixed Attenuator; 6 dB; DC to 26.5 GHz; K(m); K(f); 50 Ohm |
41KB-10 | Precision Fixed Attenuator; 10 dB; DC to 26.5 GHz; K(m) - K(f); 50 Ohm |
41KB-20 | Precision Fixed Attenuator; 20 dB; DC to 26.5 GHz; K(m) - K(f); 50 Ohm |
43KB-3 | Fixed Attenuator; 3 dB; DC to 26.5 GHz; K(m) - K(f); 50 Ohm |
43KB-6 | Fixed Attenuator; 6 dB; DC to 26.5 GHz; K(m) - K(f); 50 Ohm |
43KB-10 | Fixed Attenuator; 10 dB; DC to 26.5 GHz; K(m) - K(f); 50 Ohm |
43KB-20 | Fixed Attenuator; 20 dB; DC to 26.5 GHz; K(m) - K(f); 50 Ohm |
Precision Coaxial Adapters |
|
510-90-R | Adapter; DC to 7.5 GHz; 7/16 (f) - N(m); 50 Ohm |
510-91-R | Adapter; DC to 7.5 GHz; 7/16 (f) - N(f); 50 Ohm |
510-92-R | Adapter; DC to 7.5 GHz; 7/16 (m) - N(m); 50 Ohm |
510-93-R | N(f) to 7/16 DIN(m), DC to 3.3 GHz |
33NFNF50B | N(f) to N(f), DC to 18 GHz |
33NNF50B | N(m) to N(f), DC to 18 GHz |
33NN50B | N(m) to N(m), DC to 18 GHz |
34AN50 | Precision Adapter; DC to 18 GHz; GPC-7 - N(m); 50 Ohm |
34ANF50 | Precision Adapter; DC to 18 GHz; GPC-7 - N(f); 50 Ohm |
34NFK50 | Precision Adapter; DC to 18 GHz; N (f) - K(m); 50 Ohm |
34NFKF50 | Precision Adapter; DC to 18 GHz; N(f) - K(f); 50 Ohm |
34NK50 | Precision Adapter; DC to 18 GHz; N (m) - K(m); 50 Ohm |
34NKF50 | Precision Adapter; DC to 18 GHz; N(m) - K(f); 50 Ohm |
1091-26-R | Adapter; DC to 18 GHz; N(m) - SMA(m); 50 Ohm |
1091-27-R | Adapter; DC to 18 GHz; N(m)-SMA(f); 50 Ohm |
1091-80-R | Adapter; DC to 18 GHz; N(f)-SMA(m); 50 Ohm |
1091-81-R | Adapter; DC to 18 GHz; N(f)-SMA(f); 50 Ohm |
Sensor Calibration Utility |
|
2300-528 | Precision Termination; DC to 8 GHz; N(m); 50 Ohm |
Included Accessories
Model | Description |
---|---|
2000-1605-R | 1.5 m BNC (m) to MCX (m) cable |
2000-1606-R | 1.8 m USB A to Micro-B cable with latch |
10585-00021 | Quick Start Guide |
Repair and Calibration
Services and Support Programs
Anritsu’s repair and calibration programs help ensure your products continue to operate at peak performance and reliability. All repairs are covered by a 90-day repair warranty on parts replaced and services performed. Entrust us with your Anritsu test and measurement equipment for expert product support, fast service and competitive pricing.
MA24108A Available Services
Click on the service code that best suits your needs
Extended Service Program Support Options | 2-Year | 3-Year | 5-Year |
---|---|---|---|
Repair Only Options |
|||
Return-to-Anritsu Repair Only | ES210 | ES310 | ES510 |
Calibration Only Options |
|||
Return-to-Anritsu Standard Calibration | ES312 | ES512 | |
Return-to-Anritsu Premium Calibration | ES315 | ES515 | |
Repair with Calibration Options |
|||
Return-to-Anritsu Repair and Standard Calibration | ES313 | ES513 | |
Return-to-Anritsu Repair and Premium Calibration | ES316 | ES516 | |
Read Anritsu Service Brochure here |
Standard Service Program Support Options | Per-incident Service |
---|---|
Accredited Calibration to ISO17025 and ANSI/NCSL Z540. Test report and uncertainty data included. | Option 97 |
Standard calibration to ISO17025 and ANSI/NCSL Z540 | Option 98 |
Premium calibration to ISO17025 and ANSI/NCSL Z540. Test report and uncertainty data included. | Option 99 |
Read Anritsu Service Brochure here |
Contact us for details.