Anristu Inline Power Sensor MA2410xA
Measure a wide variety of signals from CW to LMR, Tetra, APCO/ P25, cellular, or tactical military radar and avionics
The Anritsu MA2410xA Inline Peak Power Sensors are designed to take accurate average power measurements over 2mW to 150 W, from 25 MHz to 4 GHz. The sensors employ a "dual path" architecture that enables True-RMS measurements over the entire frequency and dynamic range allowing users to measure CW, multi-tone and digitally modulated signals such as GSM/EDGE, CDMA/EV-DO, WCDMA/HSDPA, WiMAX, and TD-SCDMA. The forward direction path also includes a 4 MHz bandwidth channel that has peak and comparator/integrator circuits that add measurement functions such as PEP power, crest factor, CCDF, and burst average power. Another detection circuit on the reverse direction adds reverse power measurement capabilities including reverse power, reflection coefficient, return-loss, and SWR. The presence of a micro-controller along with signal conditioning circuitry, ADC, and power supply in the sensor makes it a complete miniature power meter.
Anritsu has two variants of Inline Sensors
- MA24103A - with frequency range from 25 MHz to 1 GHz
- MA24105A - with frequency range from 350 MHz to 4 GHz
Operation with PC
The power sensor can be used with a PC running Microsoft Windows® (including Windows 11) via USB. It comes with PowerXpert™ application data display, analysis, and sensor control. The application has abundant features like data logging, power versus time graph, single sensor display, Real time settings update, and offset table that enable quick and accurate measurements.
Operation with Anritsu Handheld Instruments
Handheld instruments having the high accuracy power meter software Option 19 can operate both Inline Peak Power Sensors. The power sensor easily connects to these instruments via a USB A/Micro-B cable. The MA2410xA sensors are currently compatible with most Anritsu handheld instruments. Refer to your instrument technical data sheet or contact your sales representative to ensure compatibility.
Model | Description |
---|---|
MA24103A | 25 MHz to 1 GHz Inline Peak Power Sensor |
MA24105A | 350 MHz to 4 GHz Inline Peak Power Sensor |
Available Accessories
Model | Description |
---|---|
Precision Coaxial Adapters |
|
510-90 | Adapter; DC to 7.5 GHz; 7/16 (f) - N(m); 50 Ohm |
34ANF50 | Precision Adapter; DC to 18 GHz; GPC-7 - N(f); 50 Ohm |
510-91 | Adapter; DC to 7.5 GHz; 7/16 (f) - N(f); 50 Ohm |
34NFK50 | Precision Adapter; DC to 18 GHz; N (f) - K(m); 50 Ohm |
510-92 | Adapter; DC to 7.5 GHz; 7/16 (m) - N(m); 50 Ohm |
34NFKF50 | Precision Adapter; DC to 18 GHz; N(f) - K(f); 50 Ohm |
34NK50 | Precision Adapter; DC to 18 GHz; N (m) - K(m); 50 Ohm |
34NFNF50 | Precision Adapter; DC to 18 GHz; N(f) - N(f); 50 Ohm |
34NKF50 | Precision Adapter; DC to 18 GHz; N(m) - K(f); 50 Ohm |
34AN50 | Precision Adapter; DC to 18 GHz; GPC-7 - N(m); 50 Ohm |
34NN50A | Precision Adapter; DC to 18 GHz; N(m) - N(m); 50 Ohm |
Attenuators, N Type (up to 18 GHz) |
|
1010-121-R | Attenuator; 40 dB; 100 Watt; DC-18 GHz; N(m)-N(f); Uni-Directional |
42N50-20 | Attenuator; 20 dB; 5 Watt; DC to 18 GHz; N(m) - N(f) |
3-1010-122 | Attenuator; 20 dB; 5 Watt; DC - 12.4 GHz; N(m)-N(f) |
42N50A-30 | Attenuator; 30 dB; 50 Watt; DC to 18 GHz; N(m) - N(f) |
3-1010-123 | Attenuator; 30 dB; 50 Watt; DC-8.5 GHz; N(m)-N(f) |
1010-127-R | Attenuator; 30 dB; 150W; DC to 3 GHz; N(m) - N(f) |
3-1010-124 | Attenuator; 40 dB; 100 watt; DC-8.5 GHz; N(f) input - N(m) output; Uni-directional |
1010-128-R | Attenuator; 40 dB; 150W; DC to 3 GHz; N(m) - N(f) |
Accessories |
|
01-200 | Calibrated torque wrench; GPC-7 and type N |
2000-1594-R | USB A - Mini B Cable with thumb screws; 5 Meters (For use with MA24104A amd MA24106A only) |
2000-1593-R | USB - A - Mini B Cable with thumb screws; 3 Meters (For use with MA24104A and MA24106A Only) |
Precision Terminations (Used with appropriate Power Attenuators) |
|
28N50-3 | Precision Termination; DC to 8 GHz; N(m); 50 Ohm |
28NF50-2 | Precision Termination; DC to 18 GHz; 40 dB; N(f); 50 Ohm |
28N50-2 | Precision Termination; DC to 18 GHz; 40 dB; N(m); 50 Ohm |
Included Accessories
Model | Description |
---|---|
2000-1606-R | 1.8 m USB 2.0 A to Micro-B cable |
Repair and Calibration
Services and Support Programs
Anritsu’s repair and calibration programs help ensure your products continue to operate at peak performance and reliability. All repairs are covered by a 90-day repair warranty on parts replaced and services performed. Entrust us with your Anritsu test and measurement equipment for expert product support, fast service and competitive pricing.
MA24103A Available Service
Click on the service code that best suits your needs
Extended Service Program Support Options | 2-Year | 3-Year | 5-Year |
---|---|---|---|
Repair Only Options |
|||
Return-to-Anritsu Repair Only | ES210 | ES310 | ES510 |
Calibration Only Options |
|||
Standard calibration to ISO17025 and ANSI/NCSL Z540 | Option 98 | ||
Premium calibration to ISO17025 and ANSI/NCSL Z540. Test report and uncertainty data included. | Option 99 |
||
Return-to-Anritsu Standard Calibration | ES312 | ES512 | |
Return-to-Anritsu Premium Calibration | ES315 | ES515 | |
Repair with Calibration Options |
|||
Return-to-Anritsu Repair and Standard Calibration | ES313 | ES513 | |
Return-to-Anritsu Repair and Premium Calibration | ES316 | ES516 | |
Read Anritsu Service Brochure here |
MA24105A Available Service
Click on the service code that best suits your needs
Extended Service Program Support Options | 2-Year | 3-Year | 5-Year |
---|---|---|---|
Repair Only Options |
|||
Return-to-Anritsu Repair Only | ES210 | ES310 | ES510 |
Calibration Only Options |
|||
Standard calibration to ISO17025 and ANSI/NCSL Z540 | Option 98 | ||
Premium calibration to ISO17025 and ANSI/NCSL Z540. Test report and uncertainty data included. | Option 99 |
||
Return-to-Anritsu Standard Calibration | ES312 | ES512 | |
Return-to-Anritsu Premium Calibration | ES315 | ES515 | |
Repair with Calibration Options |
|||
Return-to-Anritsu Repair and Standard Calibration | ES313 | ES513 | |
Return-to-Anritsu Repair and Premium Calibration | ES316 | ES516 | |
Read Anritsu Service Brochure here |
Contact us for details.