We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
Anritsu MS46131A
Modular 1-Port Vector Network Analyzer
Lightweight, compact, 1-port VNA. Control up to two VNAs from the same PC for improved Return Loss test throughput. Measure 5G devices with 8/20/43.5 GHz models.
The ShockLineTM MS46131A series consists of three modular, PC-controlled 1-port vector network analyzers (VNAs) with frequency ranges from 1 MHz to 8/20/43.5 GHz. Anritsu’s patented nonlinear transmission line (NLTL) technology VNA-on-chip technology simplifies the internal VNA architecture, reducing the size and cost of the instrument while enhancing accuracy and measurement repeatability. The ShockLine MS46131A series is small and portable enough to bring the VNA port to the device under test (DUT), improving measurement stability and simplifying test configuration by eliminating test port cables.
The ShockLine MS46131A series is ideally suited for 1-port RF and microwave applications in engineering, manufacturing, and education. All three VNA models have fast sweep speed and excellent corrected directivity making them suitable for a variety of 1-port device test applications including measuring passive 5G mmWave components.
Two independent ShockLine MS46131A VNAs can be controlled from an external user-supplied PC via USB. The series does not have any on-board memory, which simplifies their use in secure applications.
The combination of portability, performance make the ShockLine MS46131A VNA series ideal for modular passive device test applications.
Features
- 1-port VNA with frequency options from 1 MHz to 8 GHz / 20 GHz / 43.5 GHz
- Guaranteed performance to 43.5 GHz with Extended-KTM ports
- PC control takes advantage of external computer processing power and functionality
- Small and lightweight package enables direct connection to the DUT
- No on-board data storage eliminates the need for data purging in secure applications
- All ShockLine VNAs share common software supporting GUI and program compatibility
- Time domain with time gating option enables easier and faster fault identification
RF Passive Component Testing and Troubleshooting
- 1-port testing to 43.5 GHz
- Up to two 1-port VNAs controlled from a single PC
Cable testing
- Distance to fault
- Return Loss
- Phase measurements
Antenna testing
- VSWR / Return Loss
- Bandwidth
Secure Area Applications
- No data storage on unit
- Secure external computer control through direct USB connection
Tools
Model Number | Description |
---|---|
01-200 | Calibrated Torque End Wrench, GPC-7 and Type N |
01-201 | Torque End Wrench, 5/16 in, 0.9 N.m (8 lbf·in) (for tightening male devices, for SMA, 3.5 mm, 2.4 mm, K, and V connectors) |
01-203 | Torque End Wrench, 13/16 in, 0.9 N.m (8 lbf·in) (for tightening ruggedized SMA, 2.4 mm, K and V test port connectors) |
01-204 | End Wrench, 5/16 in, Universal, Circular, Open-ended (for SMA, 3.5 mm, 2.4 mm, K, and V connectors) |
Precision Automatic Calibrator Modules
Model Number | Description |
---|---|
MN25208A | 2-port USB SmartCal Module, 300 kHz to 8.5 GHz (available with connector options: -001 N(f), -002 K(f), -003 3.5 mm(f), -004 SMA(f)) |
MN25408A | 4-port USB SmartCal Module, 300 kHz to 8.5 GHz (available with N(f) connectors) |
MN25218A | 2-port USB SmartCal Module, 1 MHz to 20 GHz (available with K(f) connectors) |
MN25418A | 4-port USB SmartCal Module, 300 kHz to 20 GHz (available with K(f) connectors) |
36585K-2M | K Precision AutoCal Module, 70 kHz to 40 GHz, K(m) to K(m) |
36585K-2F | K Precision AutoCal Module, 70 kHz to 40 GHz, K(f) to K(f) |
36585K-2MF | K Precision AutoCal Module, 70 kHz to 40 GHz, K(m) to K(f) |
2000-1809-R | Serial to USB Adapter (required for 36585 AutoCal module if control PC does not have a serial port) |
Mechanical Calibration Kits
Model Number | Description |
---|---|
3650A | SMA/3.5 mm Calibration Kit, Without Sliding Loads, DC to 26.5 GHz, 50 Ω |
3650A-1 | SMA/3.5 mm Calibration Kit, With Sliding Loads, DC to 26.5 GHz, 50 Ω |
3652A | K Connector Calibration Kit, Without Sliding Loads, DC to 40 GHz, 50 Ω |
3653A | N Connector Calibration Kit, Without Sliding Loads, DC to 18 GHz, 50 Ω |
OSLN50A-8 | Precision N Male Open/Short/Load Mechanical Calibration Tee, DC to 8 GHz, 50 Ω |
OSLNF50A-8 | Precision N Female Open/Short/Load Mechanical Calibration Tee, DC to 8 GHz, 50 Ω |
TOSLN50A-8 | Precision N Male Through/Open/Short/Load Mechanical Calibration Tee, DC to 8 GHz, 50 Ω |
TOSLNF50A-8 | Precision N Female Through/Open/Short/Load Mechanical Calibration Tee, DC to 8 GHz, 50 Ω |
OSLN50A-18 | Precision N Male Open/Short/Load Mechanical Calibration Tee, DC to 18 GHz, 50 Ω |
OSLNF50A-18 | Precision N Female Open/Short/Load Mechanical Calibration Tee, DC to 18 GHz, 50 Ω |
TOSLN50A-18 | Precision N Male Through/Open/Short/Load Mechanical Calibration Tee, DC to 18 GHz, 50 Ω |
TOSLNF50A-18 | Precision N Female Through/Open/Short/Load Mechanical Calibration Tee, DC to 18 GHz, 50 Ω |
TOSLK50A-20 | Precision K Male Through/Open/Short/Load Mechanical Calibration Tee, DC to 20 GHz, 50 Ω |
TOSLKF50A-20 | Precision K Female Through/Open/Short/Load Mechanical Calibration Tee, DC to 20 GHz, 50 Ω |
TOSLK50A-40 | Precision K Male Through/Open/Short/Load Mechanical Calibration Tee, DC to 40 GHz, 50 Ω |
TOSLKF50A-40 | Precision K Female Through/Open/Short/Load Mechanical Calibration Tee, DC to 40 GHz, 50 Ω |
TOSLK50A-43.5 | Precision K Male Through/Open/Short/Load Mechanical Calibration Tee with S1P data, DC to 43.5 GHz, 50 Ω |
TOSLKF50A-43.5 | Precision K Female Through/Open/Short/Load Mechanical Calibration Tee with S1P data, DC to 43.5 GHz, 50 Ω |
Cables and Adapters
Model Number | Description |
---|---|
1091-26-R | SMA(m) to N(m), DC to 18 GHz, 50 Ω |
1091-27-R | SMA(f) to N(m), DC to 18 GHz, 50 Ω |
1091-80-R | SMA(m) to N(f), DC to 18 GHz, 50 Ω |
1091-81-R | SMA(f) to N(f), DC to 18 GHz, 50 Ω |
71693-R | Ruggedized adapter, K(f) to N(f), DC to 18 GHz, 50 Ω |
34NK50 | Precision Adapter, N(m) to K(m), DC to 18 GHz, 50 Ω |
34NKF50 | Precision Adapter, N(m) to K(f), DC to 18 GHz, 50 Ω |
34NFK50 | Precision Adapter, N(f) to K(m), DC to 18 GHz, 50 Ω |
34NFKF50 | Precision Adapter, N(f) to K(f), DC to 18 GHz, 50 Ω |
K220B | Precision Adapter, K(m) to K(m), DC to 40 GHz, 50 Ω |
K222B | Precision Adapter, K(f) to K(f), DC to 40 GHz, 50 Ω |
K224B | Precision Adapter, K(m) to K(f), DC to 40 GHz, 50 Ω |
33KK50C | Calibration Grade Adapter, K(m) to K(m), DC to 43.5 GHz, 50 Ω |
33KKF50C | Calibration Grade Adapter, K(m) to K(f), DC to 43.5 GHz, 50 Ω |
33KFKF50C | Calibration Grade Adapter, K(f) to K(f), DC to 43.5 GHz, 50 Ω |
34VFK50A | Precision Adapter, V(f) to K(m), DC to 43.5 GHz, 50 Ω |
34VFKF50A | Precision Adapter, V(f) to K(f), DC to 43.5 GHz, 50 Ω |
34VK50A | Precision Adapter, V(m) to K(m), DC to 43.5 GHz, 50 Ω |
34VKF50A | Precision Adapter, V(m) to K(f), DC to 43.5 GHz, 50 Ω |
Test Port Cables, Flexible, Ruggedized, Phase Stable
Model Number | Description |
---|---|
15NNF50-1.0B | Test Port Cable, Flexible, Phase Stable, 1.0 m (39”), DC to 18 GHz, N(f) to N(m), 50 Ω |
15NNF50-1.5B | Test Port Cable, Flexible, Phase Stable, 1.5 m (59”), DC to 18 GHz, N(f) to N(m), 50 Ω |
15NN50-1.0B | Test Port Cable, Flexible, Phase Stable, 1.0 m (39”), DC to 18 GHz, N(m) to N(m), 50 Ω |
15LL50-1.0A | Test Port Cable, Armored, Phase Stable, 1.0 m (39”), DC to 20 GHz, 3.5 mm(m) to 3.5 mm(m), 50 Ω |
15LLF50-1.0A | Test Port Cable, Armored, Phase Stable, 1.0 m (39”), DC to 20 GHz, 3.5 mm(m) to 3.5 mm(f), 50 Ω |
15KK50-1.0A | Test Port Cable, Armored, Phase Stable, 1.0 m (39”), DC to 20 GHz, K(m) to K(m), 50 Ω |
15KKF50-1.0A | Test Port Cable, Armored, Phase Stable, 1.0 m (39”), DC to 20 GHz, K(m) to K(f), 50 Ω |
3671KFS50-60 | Test Port Cable, Flexible, Phase Stable, DC to 26.5 GHz, K(f) to 3.5 mm(m), 63.5 cm, 50 Ω |
3671KFK50-60 | Test Port Cable, Flexible, Phase Stable, DC to 40 GHz, K(f) to K(m), 63.5 cm (25 in), 50 Ω |
3671KFKF50-60 | Test Port Cable, Flexible, Phase Stable, DC to 40 GHz, K(f) to K(f), 63.5 cm (25 in), 50 Ω |
3671KFK50-100 | Test Port Cable, Flexible, Phase Stable, DC to 40 GHz, K(f) to K(m), 1 m (38 in), 50 Ω |
806-304-R | Flexible Phase Stable Cable, DC to 40 GHz, 36 in (91.5 cm), K(m) – K(f), 50Ω |
806-423-R | Flexible Phase Stable Cable, DC to 43.5 GHz, 24 in (61 cm), K(f) – K(f), 50 Ω |
806-424-R | Flexible Phase Stable Cable, DC to 43.5 GHz, 24 in (61 cm), K(m) – K(f), 50 Ω |
806-425-R | Flexible Phase Stable Cable, DC to 43.5 GHz, 1 m (39.4 in), K(f) – K(f), 50 Ω |
806-426-R | Flexible Phase Stable Cable, DC to 43.5 GHz, 1 m (39.4 in), K(m) – K(f), 50 Ω |
Phase-Stable 18 GHz, 40 GHz, and 43.5 GHz Semi-Rigid Cables (Armored)
Model Number | Description |
---|---|
3670N50-1 | Test Port Cable, Armored, Semi-rigid, 30.48 cm (1 ft), DC to 18 GHz, N(m) to N(f), 50 Ω |
3670N50-2 | Test Port Cable, Armored, Semi-rigid, 60.96 cm (2 ft), DC to 18 GHz, N(m) to N(f), 50 Ω |
3670NN50-1 | Test Port Cable, Armored, Semi-rigid, 30.48 cm (1 ft), DC to 18 GHz, N(m) to N(m), 50 Ω |
3670NN50-2 | Test Port Cable, Armored, Semi-rigid, 60.96 cm (2 ft), DC to 18 GHz, N(m) to N(m), 50 Ω |
3670K50A-1 | Test Port Cable, Armored, Semi-rigid, 30.48 cm (1 ft), DC to 43.5 GHz, K(m) to K(f), 50 Ω |
3670K50A-2 | Test Port Cable, Armored, Semi-rigid, 60.96 cm (2 ft), DC to 43.5 GHz, K(m) to K(f), 50 Ω |
Repair and Calibration
Services and Support Programs
Anritsu’s repair and calibration programs help ensure your products continue to operate at peak performance and reliability. All repairs are covered by a 90-day repair warranty on parts replaced and services performed. Entrust us with your Anritsu test and measurement equipment for expert product support, fast service and competitive pricing.
MS46131A Available Services
Extended Services Program Options | 3-Year | 5-Year |
---|---|---|
Repair Only Options |
||
Return-to-Anritsu Repair Only | ES510 | |
Calibration Only Options |
||
Return-to-Anritsu Standard Calibration | ES312 | ES512 |
Return-to-Anritsu Premium Calibration | ES315 | ES515 |
Repair with Calibration Options |
||
Return-to-Anritsu Repair and Standard Calibration | ES513 | |
Return-to-Anritsu Repair and Premium Calibration | ES516 | |
Read Anritsu Service Brochure here |
Service Agreement Program Options | Per-incident Service |
---|---|
Standard calibration to ISO17025 and ANSI/NCSL Z540 | Option 98 |
Premium calibration to ISO17025 and ANSI/NCSL Z540. Test report and uncertainty data included. | Option 99 |
Read Anritsu Service Brochure here |
Contact us for details.